Fujitsu MHN2100AT, MHN2150AT, MHN2300AT, MHN2200AT manual Log Directory Data Format, 1FF

Models: MHN2150AT MHN2300AT MHN2100AT MHN2200AT

1 236
Download 236 pages 33.82 Kb
Page 149
Image 149

5.3 Host Commands

Check sum

Two’s complement of the lower byte, obtained by adding 511-byte data one byte at a time from the beginning.

Insurance failure threshold

The limit of a varying attribute value. The host compares the attribute values with the thresholds to identify a failure.

 

Table 5.10 Log Directory Data Format

 

 

 

 

 

Byte

 

 

 

Item

 

 

 

 

 

00

 

SMART Logging Version

 

01

 

 

 

 

 

 

 

 

 

 

02

 

Number of sectors of Address "01h"

 

 

 

 

 

03

 

 

 

 

 

 

Reserved

 

0B

 

 

 

 

 

 

 

 

0C

 

Number of sectors of Address "06h"

 

 

 

 

 

0D

 

 

 

 

 

 

Reserved

 

FF

 

 

 

 

 

 

 

 

 

100

 

Address 80h

 

Number of sector

 

 

 

 

101

 

 

Reserved

 

 

 

 

 

 

 

 

102

 

Address 81h

 

"102" and "13F" are both the same

 

 

 

 

13F

 

Address 9Fh

 

format as "100-101"

 

 

 

 

 

 

 

 

140

 

 

 

 

 

 

Reserved

 

1FF

 

 

 

 

 

 

 

 

 

SMART error logging

If an unrecoverable error is detected during execution of a command received by the device from the host computer, the device saves the SMART error log on the disk medium.

The host computer can issue the SMART Read Log Sector sub-command (FR register = D5h, SN register = 01h) and read the SMART error log.

C141-E120-02EN

5-73

Page 149
Image 149