Fujitsu MHN2150AT, MHN2100AT, MHN2300AT, MHN2200AT manual Security Erase Unit, Read DMA Write DMA

Models: MHN2150AT MHN2300AT MHN2100AT MHN2200AT

1 236
Download 236 pages 33.82 Kb
Page 156
Image 156

Interface

SECURITY ERASE UNIT

FROZEN MODE is canceled when the power is turned off, or when hardware is reseted. If this command is reissued in FROZEN MODE, the command is completed and FROZEN MODE remains unchanged.

Issuing this command during LOCKED MODE returns the Aborted Command error.

The following medium access commands return the Aborted Command error when the device is in LOCKED MODE:

READ DMA

WRITE DMA

SECURITY DISABLE PASSWORD

READ LONG

WRITE LONG

SECURITY FREEZE LOCK

READ MULTIPLE

WRITE MULTIPLE

SECURITY SET PASSWORD

READ SECTORS

WRITE SECTORS

SET MAX

READ VERIFY

WRITE VERIFY

FLUSH CACHE

 

SECTORS

 

 

 

 

At command issuance (I-O register contents)

1F7h(CM)

1

1

1

1

0

1

0

1

 

 

 

 

 

 

 

 

 

1F6h(DH)

x

x

x

DV

xx

 

 

 

1F5h(CH)

xx

 

 

 

 

 

 

 

1F4h(CL)

xx

 

 

 

 

 

 

 

1F3h(SN)

xx

 

 

 

 

 

 

 

1F2h(SC)

xx

 

 

 

 

 

 

 

1F1h(FR)

xx

 

 

 

 

 

 

 

At command completion (I-O register contents)

1F7h(ST)

Status information

 

 

 

 

 

 

 

 

1F6h(DH)

x

x

x

DV

xx

1F5h(CH)

xx

 

 

 

 

1F4h(CL)

xx

 

 

 

 

1F3h(SN)

xx

 

 

 

 

1F2h(SC)

xx

 

 

 

 

1F1h(ER)

Error information

 

 

 

 

 

 

 

 

5-80

C141-E120-02EN