Texas Instruments TMS320DM646x MDIO User Command Complete Interrupt Unmasked Register USERINTRAW

Models: TMS320DM646x

1 135
Download 135 pages 29.86 Kb
Page 76
Image 76
4.7MDIO User Command Complete Interrupt (Unmasked) Register (USERINTRAW)

www.ti.com

MDIO Registers

4.7MDIO User Command Complete Interrupt (Unmasked) Register (USERINTRAW)

The MDIO user command complete interrupt (unmasked) register (USERINTRAW) is shown in Figure 33 and described in Table 31.

Figure 33. MDIO User Command Complete Interrupt (Unmasked) Register (USERINTRAW)

31

 

 

16

Reserved

 

 

 

R-0

 

 

 

15

2

1

0

Reserved

 

USERINTRAW

R-0

 

R/W1C-0

LEGEND: R = Read only; R/W = Read/Write; W1C = Write 1 to clear, write of 0 has no effect; -n= value after reset

Table 31. MDIO User Command Complete Interrupt (Unmasked) Register (USERINTRAW)

Field Descriptions

Bit

Field

Value

Description

31-2

Reserved

0

Reserved

1-0

USERINTRAW

0-3h

MDIO User command complete event bits. When asserted, a bit indicates that the previously

 

 

 

scheduled PHY read or write command using that particular USERACCESS register has

 

 

 

completed. USERINTRAW[0] and USERINTRAW[1] correspond to USERACCESS0 and

 

 

 

USERACCESS1, respectively. Writing a 1 will clear the event and writing a 0 has no effect.

 

 

0

No MDIO user command complete event.

 

 

1

The previously scheduled PHY read or write command using MDIO user access register n

 

 

 

(USERACCESSn) has completed.

76

Ethernet Media Access Controller (EMAC)/Management Data Input/Output (MDIO)

SPRUEQ6–December 2007

Submit Documentation Feedback