4.14 MDIO User PHY Select Register 1 (USERPHYSEL1)

www.ti.com

MDIO Registers

4.14 MDIO User PHY Select Register 1 (USERPHYSEL1)

The MDIO user PHY select register 1 (USERPHYSEL1) is shown in Figure 40 and described in Table 38.

Figure 40. MDIO User PHY Select Register 1 (USERPHYSEL1)

31

 

 

 

 

 

16

 

 

Reserved

 

 

 

 

 

 

R-0

 

 

 

 

15

8

7

6

5

4

0

Reserved

 

LINKSEL

LINKINTENB

Rsvd

 

PHYADRMON

R-0

 

R/W-0

R/W-0

R-0

 

R/W-0

LEGEND: R/W = Read/Write; R = Read only; -n= value after reset

Table 38. MDIO User PHY Select Register 1 (USERPHYSEL1) Field Descriptions

Bit

Field

Value

Description

31-8

Reserved

0

Reserved

7

LINKSEL

 

Link status determination select bit. Default value is 0, which implies that the link status is

 

 

 

determined by the MDIO state machine. This is the only option supported on this device.

 

 

0

The link status is determined by the MDIO state machine.

 

 

1

Not supported.

6

LINKINTENB

 

Link change interrupt enable. Set to 1 to enable link change status interrupts for the PHY address

 

 

 

specified in PHYADRMON. Link change interrupts are disabled if this bit is set to 0.

 

 

0

Link change interrupts are disabled.

 

 

1

Link change status interrupts for PHY address specified in PHYADDRMON bits are enabled.

5

Reserved

0

PHY address whose link status is to be monitored.

4-0

PHYADRMON

0-1Fh

PHY address whose link status is to be monitored.