www.ti.com
Ethernet Media Access Controller (EMAC) Registers
5.4Receive Identification and Version Register (RXIDVER)
The receive identification and version register (RXIDVER) is shown in Figure 44 and described in Table 43.
Figure 44. Receive Identification and Version Register (RXIDVER)
31 |
|
| 16 |
| RXIDENT |
| |
|
|
| |
15 | 8 | 7 | 0 |
| RXMAJORVER |
| RXMINORVER |
|
|
LEGEND: R = Read only;
Table 43. Receive Identification and Version Register (RXIDVER) Field Descriptions
Bit | Field | Value | Description |
RXIDENT |
| Receive identification value. | |
|
| Ch | Current receive identification value. |
RXMAJORVER |
| Receive major version value. Revisions are indicated by a revision code taking the format | |
|
|
| RXMAJORVER.RXMINORVER. |
|
| Ah | Current receive major version value. |
RXMINORVER |
| Receive minor version value. Revisions are indicated by a revision code taking the format | |
|
|
| RXMAJORVER.RXMINORVER. |
|
| 7h | Current receive minor version value. |
5.5Receive Control Register (RXCONTROL)
The receive control register (RXCONTROL) is shown in Figure 45 and described in Table 44.
Figure 45. Receive Control Register (RXCONTROL)
31 |
| 16 |
Reserved |
|
|
|
| |
15 | 1 | 0 |
Reserved |
| RXEN |
|
LEGEND: R = Read only; R/W = Read/Write;
Table 44. Receive Control Register (RXCONTROL) Field Descriptions
Bit | Field | Value | Description |
Reserved | 0 | Reserved | |
0 | RXEN |
| Receive enable |
|
| 0 | Receive is disabled. |
|
| 1 | Receive is enabled. |
Ethernet Media Access Controller (EMAC)/Management Data Input/Output (MDIO) | 89 | |
Submit Documentation Feedback |
|
|