Xerox 180 IPS manual Table E-3.JES3FSS statement parameters continued, Item, Range of, description

Models: 180 IPS

1 200
Download 200 pages 60.45 Kb
Page 148
Image 148
Table E-3.JES3 FSS statement parameters (continued)

DEFINING THE PRINTER TO THE HOST: TCP/IP ATTACHMENT

Table E-3.JES3 FSS statement parameters (continued)

Item

 

 

Range of

 

 

description

Default

Source of value

acceptable values

Comments

Your value

 

 

 

 

 

 

DYNAMIC

NO

Installation printer

YES or NO

DYNAMIC=NO should be

 

 

 

name standards

 

specified so JES3 will keep

 

 

 

 

 

FSA active between

 

 

 

 

 

transmission of datasets.

 

 

 

 

 

 

 

FSSNAME

None

Name of FSA in

1 to 8-character

Must match value in

 

 

 

JNAME parameter

alphanumeric string

FSSNAME parameter of

 

 

 

 

 

FSSDEF statement.

 

 

 

 

 

 

 

JNAME

None

FSSNAME parameter

1 to 8-character

Must match value in

 

 

 

of FSSDEF statement

alphanumeric string

FSSNAME parameter of

 

 

 

 

 

FSSDEF statement.

 

 

 

 

 

 

 

JUNIT

ON

See comments.

(Device address,

Device address should not

 

 

 

 

Main, dest class,

be specified for TCP/IP

 

 

 

 

ON/OFF)

printers.

 

 

 

 

 

Main is name of processor

 

 

 

 

 

the FSS is to run on.

 

 

 

 

 

Dest class is destination

 

 

 

 

 

class for FSA messages.

 

 

 

 

 

ON or OFF specifies

 

 

 

 

 

whether FSA is initially

 

 

 

 

 

online or offline.

 

 

 

 

 

 

 

MODE

None

Must be FSS.

FSS

MODE=FSS must be

 

 

 

 

 

specified.

 

 

 

 

 

 

 

WC

Any class

Installation output

List of

If CLASS is specified in the

 

 

selected

class standards

alphanumeric

Work-selection criterion in

 

 

 

 

output classes,

the WS parameter, the FSA

 

 

 

 

each separated by

selects datasets that match

 

 

 

 

a comma

values specified here.

 

 

 

 

 

 

 

WS

 

Installation

Work-selection

Consider CL, R, and F.

 

 

 

preferences (see note)

criterion

See Note below and JES3

 

 

 

 

 

Initialization and Tuning

 

 

 

 

 

Reference manual for more

 

 

 

 

 

information.

 

 

 

 

 

 

 

Note: The WS parameter CL specifies that datasets with the same class as the WS parameter should be selected. D specifies that only datasets with the same destination as the DGROUP parameter should be selected. F specifies that JES3 is to pass the forms value specified on the DD or OUTPUT JCL statement to the FSA. Manual backgroundManual background

Following is an example of the JES3 initialization dataset required commands:

Table E-4.JES3 initialization dataset commands example

FSSDEFTYPE=WTR,FSSNAME=FSSTCP1,PNAME=FSSPROC1,SYSTEM=SYS1,TERM=NO

DEVICEDTYPE=PRTAFT1,JNAME=PRT7,JUNIT=(,SYS1,,OFF),FSSNAME=FSSTCP1, DGROUP=LOCAK, MODE=FSS,PM=(LINE,PAGE,SOSI1),WC=(T),WS=CL,D,F)

E-6

XEROX DOCUPRINT 96/4635/180 IPS INSTALLATION PLANNING GUIDE

Page 148
Image 148
Xerox 180 IPS Table E-3.JES3FSS statement parameters continued, Item, Range of, description, Default, Source of value