Xerox 180 IPS Printer outlet voltages—50Hz, 3.Printer50 Hz DELTA voltage, Measurement, Nominal

Models: 180 IPS

1 200
Download 200 pages 60.45 Kb
Page 62
Image 62
Printer outlet voltages—50 Hz

PRINTER SPECIFICATIONS AND REQUIREMENTS

Printer outlet voltages—50 Hz

All power outlets must have a dedicated circuit for each system equipment piece. Make sure each power cord has a separate circuit.

Note: Consult with your service representative to determine the type of plug and receptacle to be used for your 50 Hz system.

DELTA configurations—50 Hz For 50 Hz DELTA configurations, measure the DELTA connection

voltages at the power source.

Table 6-3.Printer (50 Hz) DELTA voltage

Service outlet

 

 

 

configuration

Measurement

Nominal

Range

 

 

 

 

4 Wire 220 V

Line 1 to line 2

220 V RMS

198-242 V RMS

 

 

 

 

4 Wire 220 V

Line 2 to line 3

220 V RMS

198-242 V RMS

 

 

 

 

4 Wire 220 V

Line 1 to line 3

220 V RMS

198-242 V RMS

 

 

 

 

4 Wire 230 V

Line 1 to line 2

230 V RMS

207-253 V RMS

 

 

 

 

4 Wire 230 V

Line 2 to line 3

230 V RMS

207-253 V RMS

 

 

 

 

4 Wire 230 V

Line 1 to line 3

230 V RMS

207-253 V RMS

 

 

 

 

5 Wire 240 V

Line 1 to line 2

240 V RMS

216-264 V RMS

 

 

 

 

5 Wire 240 V

Line 2 to line 3

240 V RMS

216-264 V RMS

 

 

 

 

5 Wire 240 V

Line 1 to line 3

240 V RMS

216-264 V RMS

 

 

 

 

WYE (or Star) configurations—50 Hz For the 50 Hz WYE configuration, measure the WYE or Star connection voltages at the power source.

Table 6-4.Printer (50 Hz) WYE (Star) 415 voltage

Service outlet

 

 

 

configuration

Measurement

Nominal

Range

 

 

 

 

5 Wire 415 V

Line 1 to line 2

415 V RMS

374-457 V RMS

 

 

 

 

5 Wire 415 V

Line 2 to line 3

415 V RMS

374-457 V RMS

 

 

 

 

5 Wire 415 V

Line 1 to line 3

415 V RMS

374-457 V RMS

 

 

 

 

5 Wire 415 V

Line 1 to neutral

240 V RMS

216-264 V RMS

 

 

 

 

5 Wire 415 V

Line 2 to neutral

240 V RMS

216-264 V RMS

 

 

 

 

5 Wire 415 V

Line 3 to neutral

240 V RMS

216-264 V RMS

 

 

 

 

6-4

XEROX DOCUPRINT 96/4635/180 IPS INSTALLATION PLANNING GUIDE

Page 62
Image 62
Xerox 180 IPS Printer outlet voltages—50Hz, 3.Printer50 Hz DELTA voltage, Measurement, 4.Printer50 Hz WYE Star 415 voltage