PRINTER SPECIFICATIONS AND REQUIREMENTS

Environmental specifications

When you select a site location for your DocuPrint printer, avoid environments with extreme variations in temperature and other hazards, such as excessive dust or humidity. Recommended environmental ranges for the work area are as follows:

Table 6-6.Environmental specifications for 96/4635/180 printers

Condition

 

Range

 

 

 

Operating

Recommended:

68° F to 76° F /

temperature:

 

20° C to 24° C

 

Minimum:

50° F / 10° C

 

Maximum:

85° F / 29° C

 

 

 

Humidity:

Recommended:

45% ±10%

 

Minimum:

30%

 

Maximum:

65%

 

 

Altitude:

Normal: Up to 6,000 feet / 1,830 m

 

 

above sea level

 

Maximum:

9,000 feet / 2,743 m above

 

 

sea level.

 

 

 

Heat dissipation:

 

 

96 and 4635

Operating:

28,140 BTU/hour

(2-stacker system)

Standby:

4,454 BTU/hour

 

Energy Saver:

2,700 BTU/hour

180

Operating:

32,770 BTU/hour

(2-stacker system)

Standby:

4,454 BTU/hour

 

Energy Saver:

2,700 BTU/hour

 

 

 

Audible noise:

Operating:

 

 

Continuous:

82 dB(A)

 

Impulse:

82 dB(A)

 

Standby:

 

 

Continuous:

52 dB(A)

 

Impulse:

N/A

 

 

 

6-6

XEROX DOCUPRINT 96/4635/180 IPS INSTALLATION PLANNING GUIDE

Page 64
Image 64
Xerox 180 IPS manual Environmental specifications