Xerox 180 IPS power requirements, Dimensions depth, Heat, Device, width, height, Weight, printer

Models: 180 IPS

1 200
Download 200 pages 60.45 Kb
Page 57
Image 57
power requirements

CONTROLLER SPECIFICATIONS AND REQUIREMENTS

Printer controller hardware specifications and requirements summary

The following table summarizes the specifications and electrical requirements of your DocuPrint IPS printer controller hardware components.

For a summary of printer hardware specifications and requirements, refer to the “Printer specifications and requirements” chapter of this guide. Contact your service representative if you have questions not specifically addressed in this guide.

Table 5-3.96/4635/180 IPS printer controller specifications and

 

 

 

power requirements

 

 

 

 

 

 

 

 

Dimensions (depth,

 

Heat

 

 

Device

width, height)

Weight

dissipation

Power requirements

Cable lengths

 

 

 

 

 

 

Host Channel

d=15 in. / 40.8 cm

26 lbs. 10

N/A

120 VAC within 6 feet;

Bus and tag

Unit (HCU)

h=5 in. / 12.6 cm

oz. / 12.4

 

120 volt at 2 amps or

cables must

(channel-

w= 16 in. / 41.6 cm

kgs

 

240 volt at 1 amp

conform to host

attached

 

 

 

 

system

systems only)

 

 

 

 

requirements

 

 

 

 

 

(200 to 400 ft. /

 

 

 

 

 

66.7 to 133.3 m)

 

 

 

 

 

and

 

 

 

 

 

accommodate

 

 

 

 

 

system setup.

 

 

 

 

 

 

Processor

d=16.1 in. / 40.9 cm

27 lbs. /

1,100 Btu

Sun Ultra 2 (60 Hz):

Power: 8 ft. /

 

w=16.4 in. / 41.7 cm

12.7 kgs

per hours

100 to 240 VAC,

2.1 m

 

h= 3 in. / 7.6 cm

 

 

15 amp, 0.4 KVA,

Interface to

 

 

 

 

5-15R NEMA

 

 

 

 

printer:

 

 

 

 

 

 

 

 

 

 

20 ft. / 6.1 m

 

 

 

 

Sun Ultra 2 (50 Hz):

usable length

 

 

 

 

 

 

 

 

 

100 to 240 VAC,

 

 

 

 

 

15 amp, 0.4 KVA

 

 

 

 

 

Sun Ultra 60 (60 Hz):

 

 

 

 

 

100 to 240 VAC,

 

 

 

 

 

15 amp, 0.4 KVA,

 

 

 

 

 

5-15R NEMA

 

 

 

 

 

Sun Ultra 60 (50 Hz):

 

 

 

 

 

100 to 240 VAC,

 

 

 

 

 

15 amp, 0.4 KVA

 

 

 

 

 

 

 

Monitor

d=6.1 in. / 41cm

61 lbs. /

408 Btu

100-120 ~ VAC,

Video cable to

 

w=18.1 in. / 46 cm

27.7 kg

per hour

1 phase, 50-60 Hz,

processor:

 

h=17.7 in. / 45 cm

 

 

3.0 amp, 0.4 KVA

46 in. / 1.17 m

 

 

 

 

200-240 ~ VAC,

Power: 8 ft. /

 

 

 

 

1 phase, 50-60 Hz,

2.4 m

 

 

 

 

2.0 amp, 0.4 KVA

 

 

 

 

 

 

 

4 mm cartridge

d=12.2 in. / 31 cm

8 lbs. /

---

100-120/200-240 VAC,

SCSI cable to

tape drive

w=7.5 in. / 19 cm

6.6 kg

 

0.8/0.4 amp, 47-63 Hz

processor or

 

h=2.8 in. / 7 cm

 

 

 

additional SCSI

 

 

 

 

 

device:

 

 

 

 

 

28 in. / 71 cm

 

 

 

 

 

 

XEROX DOCUPRINT 96/4635/180 IPS INSTALLATION PLANNING GUIDE