Table 5.4 Information to be read by IDENTIFY DEVICE command (1 of 3)
Word | Value |
| Description |
|
0 | X‘0C5A’ | General Configuration *1 |
|
|
1 | X‘0D3E’ | Number of cylinders | MPA3017AT: X‘0D3E’ |
|
| X‘13DE’ |
| MPA3026AT: X‘13DE’ |
|
| X‘1A7C’ |
| MPA3035AT: X‘1A7C’ |
|
| X‘2352’ |
| MPA3043AT: X‘2352’ |
|
| X‘2A62’ |
| MPA3052AT: X‘2A62’ |
|
2 | X‘0000’ | Reserved |
|
|
3 | X‘0010’ or | Number of Heads | MPA3017AT: X‘0010’ |
|
| X‘000F’ |
| MPA3026AT: X‘0010’ |
|
|
|
| MPA3035AT: X‘0010’ |
|
|
|
| MPA3043AT: X‘000F’ |
|
|
|
| MPA3052AT: X‘000F’ |
|
4 | X‘0000’ | Undefined |
|
|
5 | X‘0000’ | Undefined |
|
|
6 | X‘003F’ | Number of sectors per track |
|
|
X‘000000000000’ | Undefined |
|
| |
– | Serial number (ASCII code) *2 |
|
| |
X‘00000000’ | Vendor specific |
|
| |
22 | X‘0004’ | Number of ECC bytes transferred at READ LONG or WRITE LONG command | ||
– | Firmware revision (ASCII code) *3 |
|
| |
– | Model number (ASCII code) *4 |
|
| |
47 | X‘8020’ | Maximum number of sectors per interrupt on READ/WRITE MULTIPLE command | ||
48 | X‘0000’ | Reserved |
|
|
49 | X‘0B00’ | Capabilities *5 |
|
|
50 | X‘0000’ | Reserved |
|
|
51 | X‘0200’ | PIO data transfer mode *6 |
|
|
52 | X‘0000’ | Reserved |
|
|
53 | X‘0003’ or | Enable/disable setting of words |
| |
| X‘0007’ |
|
|
|
54 | (Variable) | umber of current Cylinders |
|
|
55 | (Variable) | Number of current Head |
|
|
56 | (Variable) | Number of current sectors per track |
|
|
(Variable) | Total number of current sectors |
|
| |
59 | *8 | Transfer sector count currently set by READ/WRITE MULTIPLE command | ||
X‘00342778’ | Total number of user addressable sectors (LBA mode only) | MPA3017AT: X‘00342778’ | ||
| X‘004E3B34’ |
|
| MPA3026AT: X‘004E3B34’ |
| X‘00684EF0’ |
|
| MPA3035AT: X‘00684EF0’ |
| X‘008262AC’ |
|
| MPA3043AT: X‘008262AC’ |
| X‘009C7668’ |
|
| MPA3052AT: X‘009C7668’ |
62 | X‘0000’ | Reserved |
|
|
63 | X‘xx07’ | Multiword DMA transfer mode *9 |
|
|
64 | X‘0003’ | Advance PIO transfer mode support status *10 |
| |
65 | X‘0078’ | Minimum multiword DMA transfer cycle time per word : 120 [ns] | ||
66 | X‘0078’ | Manufacturer's recommended DMA transfer cycle time : 120 [ns] | ||
67 | X‘00F0’ | Minimum PIO transfer cycle time without flow control : 240 [ns] | ||
68 | X‘0078’ | Minimum PIO transfer cycle time with IORDY flow control : 120 [ns] | ||
X‘00’ | Reserved |
|
| |
80 | X‘000E’ | Major version number *11 |
|
|
81 | X‘0000’ | Minor version number (not reported) |
|
|
82 | X‘0009’ | Support of command sets *12 |
|
|
83 | X‘4000’ | Support of command sets (fixed) |
|
|
X‘00’ | Reserved |
|
| |
88 | X‘0000’ or | Ultra DMA modes *13 |
|
|
| X‘0X07’ |
|
|
|
5 - 30 |