Figure 5.9 PIO data transfer timing

t0

Addresses

 

 

 

t1

 

t2

 

 

 

t9

 

 

 

 

 

DIOR-/DIOW-

 

 

 

 

 

 

 

 

 

 

 

 

t2i

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Write data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DD0-DD15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t3

 

 

 

t4

 

 

 

 

 

Read data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DD0-DD15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t5

 

 

 

 

 

 

 

 

 

t6

 

 

t8

 

IOCS16-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IORDY

 

t10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Symbol

 

 

Timing parameter

 

 

 

 

 

 

 

 

 

 

 

 

Min.

 

Max.

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t0

 

Cycle time

 

 

 

 

 

 

 

 

 

 

120

 

ns

 

 

 

 

 

 

 

 

t1

 

Data register selection setup time for DIOR-/DIOW-

 

25

 

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t2

 

Pulse width of DIOR-/DIOW-

 

 

 

 

 

 

 

 

 

 

70

 

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t2i

 

Recovery time of DIOR-/DIOW-

 

 

 

 

 

 

 

 

 

 

25

 

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t3

 

Data setup time for DIOW-

 

 

 

 

 

 

 

 

 

 

20

 

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t4

 

Data hold time for DIOW-

 

 

 

 

 

 

 

 

 

 

10

 

ns

 

 

 

 

 

 

 

 

 

 

 

t5

 

Time from DIOR- assertion to read data available

 

 

 

 

20

 

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t6

 

Data hold time for DIOR-

 

 

 

 

 

 

 

 

 

 

5

 

ns

 

 

 

 

 

 

 

 

 

 

 

t7

 

Time from Data register selection to IOCS16- assertion

 

 

 

 

40

 

ns

 

 

 

 

 

 

 

 

 

 

 

t8

 

Time from Data register selection reset to IOCS16- negation

 

 

 

 

30

 

ns

 

 

 

 

 

 

 

 

 

 

 

t9

 

Data register selection hold time for DIOR-/DIOW-

 

 

 

 

10

 

ns

 

 

 

 

 

 

 

 

 

 

 

t10

 

Time from DIOR-/DIOW- assertion to IORDY "low" level

 

 

 

 

35

 

ns

 

 

 

 

 

 

 

 

t11

 

Time from validity of read data to IORDY "high" level

 

0

 

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t12

 

Pulse width of IORDY

 

 

 

 

 

 

 

 

 

 

 

 

 

1,250

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 