Fujitsu MPA3052AT, MPA3043AT, MPA3026AT, MPA3035AT manual Address Translation, Default parameters

Models: MPA3017AT MPA3035AT MPA3026AT MPA3052AT MPA3043AT

1 176
Download 176 pages 49.61 Kb
Page 156
Image 156

6.2Address Translation

When the IDD receives any command which involves access to the disk medium, the IDD always implements the address translation from the logical address (a host-specified address) to the physical address (logical to physical address translation).

Following subsections explains the CHS translation mode.

6.2.1Default parameters

In the logical to physical address translation, the logical cylinder, head, and sector addresses are translated to the physical cylinder, head, and sector addresses based on the number of heads and the number of sectors per track which are specified with an INITIALIZE DEVICE PARAMETERS command. This is called as the current translation mode.

If the number of heads and the number of sectors are not specified with an INITIALIZE DEVICE PARAMETERS command, the default values listed in Table 6.1 are used. This is called as the default translation mode. The parameters in Table 6.1 are called BIOS specification.

 

Table 6.1

Default parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

MPA

MPA

MPA

MPA

MPA

 

 

 

3052AT

3043AT

3035AT

3026AT

3017AT

 

 

 

 

 

 

 

 

 

Number of cylinders

 

10,850

9,042

6,780

5,086

3,390

Parameters

 

 

 

 

 

 

 

Number of head

 

15

 

16

 

 

(logical)

 

 

 

 

 

 

 

 

 

 

 

 

Number of sectors/track

 

63

 

 

 

 

 

 

 

 

 

 

 

 

Formatted capacity (MB)

 

5,249.6

4,374.8

3,499.1

2,624.8

1,748.5

 

 

 

 

 

 

 

 

As long as the formatted capacity of the IDD does not exceed the value shown on Table 6.1, the host can freely specify the number of cylinders, heads, and sectors per track.

Generally, the device recognizes the number of heads and sectors per track with the INITIALIZE DEVICE PARAMETER command. However, it cannot recognizes the number of cylinders. In other words, there is no way for the device to recognize a host access area on logical cylinders. Thus the host should manage cylinder access to the device.

The host can specify a logical address freely within an area where an address can be specified (within the specified number of cylinders, heads, and sectors per track) in the current translation mode.

The host can read an addressable parameter information from the device by the IDENTIFY DEVICE command (Words 54 to 56).

6 - 6

C141-E034-02EN

Page 156
Image 156
Fujitsu MPA3052AT, MPA3043AT, MPA3026AT, MPA3035AT, MPA3017AT manual Address Translation, Default parameters