(3)Current Requirements and Power Dissipation Table 1.3 lists the current and power dissipation.
Table 1.3 Current and power dissipation
Mode of |
| Typical RMS current (*1) |
|
| Typical Power (*2) |
| |||
Operation |
|
|
|
|
|
| |||
| +12 V |
| +5 V |
|
|
|
|
| |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
Model | MPA | MPA | MPA | All Models | MPA |
| MPA |
| MPA |
| 3017AT | 3026AT | 3043AT |
| 3017AT |
| 3026AT |
| 3043AT |
|
| MPA | MPA |
|
|
| MPA |
| MPA |
|
| 3035AT | 3052AT |
|
|
| 3035AT |
| 3052AT |
|
|
|
|
|
|
|
|
|
|
Spin up |
| 1.3 A |
| 0.520 A |
|
| 18.2 watts |
| |
|
| 1.5 A peak |
| 0.6 A peak |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Idle (Ready) (*3) | 0.120 A | 0.155 A | 0.185 A | 0.443 A | 3.66 watts |
| 4.08 watts |
| 4.44 watts |
|
|
|
|
|
|
|
|
|
|
R/W (On Track) | 0.130 A | 0.160 A | 0.190 A | 0.620 A | 4.66 watts |
| 5.02 watts |
| 5.38 watts |
(*4) |
|
| |||||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
Seek (Random) | 0.370 A | 0.380 A | 0.425 A | 0.520 A | 7.04 watts |
| 7.16 watts |
| 7.70 watts |
(*5) |
|
| |||||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
Standby |
| 0.01 A |
| 0.400 A |
|
| 2.12 watts |
| |
|
|
|
|
|
|
|
|
| |
Sleep |
| 0.01 A |
| 0.350 A |
|
| 1.87 watts |
| |
|
|
|
|
|
|
|
|
|
|
*1 Current is typical rms except for spin up.
*2 Power requirements reflect nominal values for +12V and +5V power.
*3 Idle mode is in effect when the drive is not reading, writing, seeking, or executing any commands.
*4 R/W mode is defined as 50% read operations and 50% write operations on a single physical track.
*5 Seek mode is defined as continuous random seek operations with minimum controller delay.
1 - 6 |