Fujitsu MPA3043AT, MPA3052AT, MPA3026AT, MPA3035AT, MPA3017AT 4 Response to diagnostic command

Models: MPA3017AT MPA3035AT MPA3026AT MPA3052AT MPA3043AT

1 176
Download 176 pages 49.61 Kb
Page 155
Image 155
6.1.4Response to diagnostic command

6.1.4Response to diagnostic command

When the master device receives an EXECUTE DEVICE DIAGNOSTIC command and the slave device is present, the master device checks the PDIAG- signal for up to 6 seconds to see if the slave device has completed the self-diagnosis successfully.

The master device does not check the DASP- signal.

After the slave device receives the EXECUTE DEVICE DIAGNOSTIC command, it shall report the result of the self-diagnostics to the master device as described below:

PDIAG- signal: negated within 1 ms and asserted within 5 seconds

When the IDD is set to a slave device, the IDD asserts the DASP- signal when negating the PDIAG- signal, and negates the DASP- signal when asserting the PDIAG- signal.

X'1F7' Reg.

Write

Master device

Status Reg.

BSY bit

Max. 6 sec.

Figure 6.4 Response to diagnostic command If the slave device is preset, DASP- signal is checked for up to

Manual background 6 seconds.

Slave device

BSY bit

Max. 1 ms.

PDIAG-

DASP-

Max. 5 sec.

Figure 6.4 Response to diagnostic command

C141-E034-02EN

6 - 5

Page 155
Image 155
Fujitsu MPA3043AT, MPA3052AT, MPA3026AT, MPA3035AT, MPA3017AT manual 4 Response to diagnostic command