Fujitsu MPA3026AT, MPA3043AT, MPA3052AT, MPA3035AT manual 5 Surface temperature measurement points

Models: MPA3017AT MPA3035AT MPA3026AT MPA3052AT MPA3043AT

1 176
Download 176 pages 49.61 Kb
Page 32
Image 32
Figure 3.5 Surface temperature measurement points

(4)Ambient temperature

The temperature conditions for a disk drive mounted in a cabinet refer to the ambient temperature at a point 3 cm from the disk drive. Pay attention to the air flow to prevent the DE surface temperature from exceeding 60°C.

Provide air circulation in the cabinet such that the PCA side, in particular, receives sufficient cooling. To check the cooling efficiency, measure the surface temperatures of the DE. Regardless of the ambient temperature, this surface temperature must meet the standards listed in Table 3.1. Figure 3.5 shows the temperature measurement point.

1

Figure 3.5 Surface temperature measurement points

Table 3.1 Surface temperature measurement points and standard values

No.

 

Measurement point

Temperature

 

 

 

 

1

DE cover

 

60°C max

 

 

 

 

C141-E034-02EN

3 - 5

Page 32
Image 32
Fujitsu MPA3026AT 5 Surface temperature measurement points, 1 Surface temperature measurement points and standard values