Replacement of non-hot-plug components

CSS components

ÊOpen the server (see “Opening/closing the housing” on page 114).

Figure 36: Example: Diagnostic LEDs on memory board B

ÊUse the diagnostic LEDs (1-8) to identify the faulty memory module.

The diagnostic LED lights up/flashes orange and indicates the slot on the memory board (1-8) that is occupied by the faulty memory module.

ÊMake a note of which LED (1-8) on which memory board (A-D) is lit/flashing orange.

ÊExit all applications and shut down the server properly (see section “Switching the server on and off” on page 67).

ÊPull all power plugs out of the insulated sockets of the rack's internal power supply.

106

Operating manual

RX600 S4

Page 106
Image 106
Fujitsu RX600 manual Replacement of non-hot-plug components, Open the server see Opening/closing the housing on