Switching the server on and off

Starting up and operation

Switching the server off

The power-on indicator lights up green (item 6 in figure 13 on page 55).

ÊShut down the operating system properly.

The server is switched off automatically and goes into standby mode. The power-on indicator lights up orange.

IIf the operating system does not switch the server off automatically, press the On/Off button for at least four seconds and/or send a corresponding control signal.

Other On/Off options

Besides the On/Off button, the server can be switched ON and OFF in the following ways:

Specified switch-on time/switch-off time

The server is switched ON or OFF at a time specified in the ServerView program

Ring Indicator

The server is switched on by an internal or external modem.

Wake On LAN (WOL)

The server is switched on by a command via the LAN (Magic Packet).

After power failure

The server automatically reboots following a power failure (depending of the settings in the BIOS).

Power button override

The server can be switched off immediately by pressing and holding the On/Off button (approx. 4-5 sec.).

VCAUTION!

There is a risk that data may be lost.

IPMI

The server is switched on from an IPMI console (via the COM1 serial interface or the RJ45 LAN interface).