Rack installation/removal of server

Hardware installation

IFor better orientation the height units are marked on the support uprights.

1

3

2

Figure 4: Mounting the telescopic rails in the PRIMECENTER Rack

ÊPosition the left vario support system with mounted telescopic rail (1) on the support bracket (insert retaining bolts).

ÊPress the left rail together until its front end passes behind the front left support upright, then release.

ÊFasten the rod with a screw (M5) to the left front support upright (2).

INo nuts are required to secure the telescopic rails as the fixing holes on the rails are threaded.

ÊInsert the cage nut at the height of the server's knurled screw in the left front support upright (3).

ÊRepeat the steps for the right vario support system with mounted telescopic rail (fastened to the front and rear right support upright).

ÊInsert the cage nut at the height of the server's knurled screw in the right front support upright.

44

Operating manual

RX600 S4

Page 44
Image 44
Fujitsu RX600 manual Mounting the telescopic rails in the Primecenter Rack