Hot-plug components

CSS components

8.1.3Replacing hot-plug main memory fans

VCAUTION!

The actions described in this section may only be performed by personnel with the appropriate technical training. Any unauthorized openings and improper repairs could expose the user to risks (electric shock, fire hazards) and could also damage the equipment.

Please observe the safety information in chapter “Important infor- mation” on page 23.

The server has two redundant fan units (1+1). Each fan unit consists of two separate hot-plug fans. The fans are only accessible when the server is open.

A possible fan fault is reported by the CSS indicator lighting up on the front and rear of the server or displayed on the ServerView Local Service Display (for more information about the behavior of these indicators, see chapter “Starting up and operation” on page 55 and the "Customer Self Service (CSS)" manual on the ServerBooks DVD).

A fan failure is reported by the CSS indicator flashing on the front and rear of the server or displayed on the ServerView Local Service Display (for more infor- mation about the behavior of these indicators, see chapter “Starting up and operation” on page 55 and the "Customer Self Service (CSS)" manual on the ServerBooks DVD).

When the server is open, the faulty fan can be identified by the corresponding LED (see figure 24 on page 87) and can be replaced while the system is running.

86

Operating manual

RX600 S4

Page 86
Image 86
Fujitsu RX600 manual Replacing hot-plug main memory fans