Furuno 16 manual Data report menu regular interval reporting

Models: 16

1 187
Download 187 pages 48.57 Kb
Page 133
Image 133
Data report menu (regular interval reporting)

5. DATA REPORTING AND POLLING

13.Choose DNID (Data Network ID) desired and press the [Enter] key. (LES ID and Member No. are automatically selected according to DNID.)14. Press the [] key to choose Activation.

14.Press the [Enter] key to open the activation options window.

15.Press the [↓] or [↑] key to choose “Regular Interval” or “Daily” as appropriate.

16.Press the [Enter] key to close the window.

17.Do one of the following depending on the selection you made at step 15. “Regular Interval” selected at step 15

(1)Press the [] key to choose Interval Time.

(2)Press the [Enter] key to open the interval time entry window.

(3)Key in the interval time. The interval should be at least 10 minutes.

(4)Press the [Enter] key to close the window.

(5)Press the [] key to choose Report Times.

(6)Press the [Enter] key to open the report times entry window.

(7)Key in the report times, or press the [Back Space] key to display “---“ to choose “No Limit” to transmit data until the “Status” setting is turned OFF.

(8)Press the [Enter] key to close the window.

“Daily” selected at step 15

(1)Press the [] key to choose Start Time 1.

(2)Press the [Enter] key to open the start time entry window.

(3)Key in the start time, in 24-hour notation.

(4)Press the [Enter] key to close the window.

(5)If necessary enter start times for Start Time 2-4.

18.Press the [Esc] key to show the update window.

 

 

Data Report

 

 

 

 

 

 

 

 

 

 

 

 

Data Report Programming

 

 

 

 

 

 

Status

OFF

 

 

 

 

 

 

Report Length

Position and Course/Speed

 

Destination

 

 

 

 

 

 

 

 

DNID

 

 

 

 

 

 

 

 

LES ID

 

 

 

 

 

 

 

 

Member No.

 

 

 

 

 

 

 

 

Activation

Regular Interval

 

 

 

Interval Time

01:00

 

 

 

 

 

 

 

 

24 (- - - : No Limit)

 

Report Times

 

Start Time1

- - : - -

 

 

Update

 

 

Start Time2

- - : - -

 

 

 

 

 

 

 

 

 

 

 

Start Time3

- - : - -

 

 

 

 

No

 

 

 

Yes

 

 

 

Start Time4

- - : - -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data report menu (regular interval reporting)

19.Yes is selected; press the [Enter] key to register settings.

20.Press the [Esc] key to return to the standby display.

5-3

Page 133
Image 133