Furuno 16 Replacing the Fuse, DCE Memory, Bber, Send Level, RX AGC Level, REF Offset Freq, Speed

Models: 16

1 187
Download 187 pages 48.57 Kb
Page 158
Image 158
DCE Memory:

7. MAINTENANCE, TROUBLESHOOTING

DCE Memory:

Memory remaining in communication unit

BBER:

Bulletin Board Error Rate (%)

C/N:

Check of circuit status with LES, receiving circuit in

 

antenna unit and RF CON/CPU Board in

 

communication unit. OK appears for figure greater

Send Level:

than 31.

TX level check. At transmission, OK appears for

 

figure greater than 123. At reception, OK appears for

RX AGC Level:

figure lower than 32.

Check of the receiving circuit of the antenna unit and

 

the RF CON/CPU Board in the communication unit.

REF Offset Freq:

OK appears for figure greater than 60.

OK appears for figure lower than 150.

Synthe Local:

Check of RF CON/CPU Board.

VCXO Control:

Oscillator frequency control value.

Antenna Power Supply:

NG appears for discontinuity or short in antenna

 

cable. OK is shown if the antenna is receiving

Temperature*:

electrical power.

Blank

Water Current*

 

Direction:

Blank

Speed:

Blank

Depth*:

Blank

*= Requires data from appropriate sensor.

7.5Replacing the Fuse

The fuse (12 VDC: 10A, 24 VDC: 5A) in the power cable protects the communications unit from overcurrent and reverse polarity. If the fuse blows, find out the case before replacing it. If it blows again after replacement, contact your dealer for advice. Be sure to use the correct fuse. Use of a wrong will damage the equipment and void the warranty.

Send Level: CAUTION

Use the proper fuse.

Use of a wrong fuse can result in damage to the equipment.

Fuse

12 VDC

Type: FGBO 125V 10A PBF

Code No.: 000-155-826-10

24 VDC

Type: FGBO-A 125V 5A PBF

Code No.: 000-155-853-10

7-8

Page 158
Image 158