Control head modification procedure

1.Unfasten eight screws (M4X8) on the underside of the control head. Unplug connectors P314, P312 and P317 from the control head. Separate the KB bot- tom plate from the control head.

2.Unfasten the screw (M4) fixing the ground terminal and two screws (M4X8) fixing the clamp. Remove the connection cable assy.

3.Unfasten two screws (M6X12) from the inside of the bottom plate of the control head to dismount the handle.

4.Replace the cable assy. with cable assy. UL2464SB2-0P/1P (10 m, supplied) as below and reassemble the control head.

P312 FX Connector

KB

BOTTOM

 

PLATE

Upset Screw

M6X12 (2 pcs.)

KB Clamp

Handle

KB Fixing Plate

Screw

M4X8 (8 pcs.)

 

 

J317

 

Lay cable in slot.

J314

(underside)

 

 

 

J312

 

 

 

 

(underside)

 

 

 

 

 

(underside)

 

Earth Wire

P314 XH3P

Replace with

Spacer Pan-head Screw M4X8 (2 pcs.)

cable assy. in

Be careful not to pinch cable between

kit.

KB clamp and spacer.

 

Figure 1-16 Control head

1-13

Page 20
Image 20
Furuno FR-2125V installation manual Plate, Control head modification procedure