Furuno FR-2125V Changing AC Power Specification, How to attach NH connector, Power Spec Antenna

Models: FR-2125V

1 90
Download 90 pages 12.16 Kb
Page 34
Image 34

How to attach NH connector

HOW TO ATTACH NH CONNECTOR TO SIGNAL CABLE

NH connector wire

NH connector housing

1Insert NH connector wire into NH connector housing.

Shrink tubing

20mm

2Cut shrink tubing in 20 mm lengths and slip onto each wire.

Solder

 

3 Solder connector

4 Heat shrink

to signal cable.

tubing with solder-

 

ing iron.

Figure 2-14 How to attach NH connector

2.3 Changing AC Power Specification

For 100 VAC or 220 VAC power, add or delete jumper wires on the PTU Board and change the power fuses inside the display unit as shown in the table below accord- ing to ship’s mains. The figure below shows the location of the power fuses and the jumper wires on the PTU Board.

Table 2-2 Jumper wire setting on the PTU board, fuse rating and power specification

PCB

Power Spec.

Antenna

JP1

JP2

JP3

JP4

JP91

JP92

Power

rpm

Fuses

 

 

 

 

 

 

 

 

03P9245A

100/110/115 VAC

24 rpm

YES

YES

YES

NO

NO

NO

10A

03P9245C

100/110/115 VAC

42 rpm

YES

YES

YES

NO

YES

YES

 

03P9245D

220/230 VAC

24 rpm

NO

NO

NO

YES

NO

NO

5A

03P9245F

220/230 VAC

42 rpm

NO

NO

NO

YES

YES

YES

 

 

 

Jumper wire to use:

 

 

 

 

 

 

 

JP1: 0.8 dia. gilded wire

 

 

 

 

 

 

JP2, JP3, JP4, JP91, JP92: type ERD-S2TCOV

 

Fuse

03P9245

C11 C12

JP1

 

 

 

T1

 

JP2

 

JP92

 

 

 

 

 

 

 

 

U92

 

 

 

JP3

 

 

 

 

 

JP4

 

 

 

JP91

 

 

 

 

 

T21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PTU Board

Figure 2-15 Display unit, inside view

2-12

Page 34
Image 34
Furuno FR-2125V Changing AC Power Specification, How to attach NH connector, Power Spec Antenna, JP91 JP92, Rpm Fuses