How to attach NH connector
HOW TO ATTACH NH CONNECTOR TO SIGNAL CABLE
NH connector wire
NH connector housing
1Insert NH connector wire into NH connector housing.
Shrink tubing
20mm
2Cut shrink tubing in 20 mm lengths and slip onto each wire.
Solder |
|
3 Solder connector | 4 Heat shrink |
to signal cable. | tubing with solder- |
| ing iron. |
Figure 2-14 How to attach NH connector
2.3 Changing AC Power Specification
For 100 VAC or 220 VAC power, add or delete jumper wires on the PTU Board and change the power fuses inside the display unit as shown in the table below accord- ing to ship’s mains. The figure below shows the location of the power fuses and the jumper wires on the PTU Board.
Table
PCB | Power Spec. | Antenna | JP1 | JP2 | JP3 | JP4 | JP91 | JP92 | Power | |
rpm | Fuses | |||||||||
|
|
|
|
|
|
|
| |||
03P9245A | 100/110/115 VAC | 24 rpm | YES | YES | YES | NO | NO | NO | 10A | |
03P9245C | 100/110/115 VAC | 42 rpm | YES | YES | YES | NO | YES | YES | ||
| ||||||||||
03P9245D | 220/230 VAC | 24 rpm | NO | NO | NO | YES | NO | NO | 5A | |
03P9245F | 220/230 VAC | 42 rpm | NO | NO | NO | YES | YES | YES | ||
| ||||||||||
|
| Jumper wire to use: |
|
|
|
|
| |||
|
| JP1: 0.8 dia. gilded wire |
|
|
|
| ||||
|
| JP2, JP3, JP4, JP91, JP92: type |
|
Fuse
03P9245
C11 C12
JP1
|
|
| T1 |
| |||
JP2 |
| JP92 |
|
|
| ||
|
|
|
|
| U92 | ||
|
|
| JP3 | ||||
|
|
| |||||
|
| JP4 |
|
|
| JP91 | |
|
|
|
|
| |||
T21 |
|
|
| ||||
|
|
|
|
| |||
|
|
|
|
|
|
PTU Board