3.7 Confirming Magnetron Heater Voltage
Magnetron heater voltage is adjusted at the factory. However, confirm that it is within the prescribed rating.
Table 3-1 Magnetron heater voltage rating
Rating | |
|
|
8.2 | |
|
|
TX, max range | 6.5 |
|
|
1.Press [RADAR MENU] [0] [0] [0] [2] [0] to open the INITIAL SETTING2 menu.
2.Press [5] to select the 5. SCANNER STOPPED field and the TX option.
3.Disconnect connector P821 from the antenna unit.
4.Turn off the ANTENNA switch in the tuning compartment in the display unit.
ANTENNA switch
ON
OFF
PM
ANTENNA
TUNE
DEGAUSS ERROR
Figure 3-4 Antenna switch in tuning compartment
5.Turn off screen brilliance.
6.Measure voltage between pins #12(+) and
7.If the voltage is not within the rating shown in Table
J611
J801
VR1
J821
Figure 3-5 RFC Board
8. Set 5. SCANNER STOPPED on the INITIAL SETTING2 menu to