9. OTHERS MENU

TM DISPLAY RANGE: Selects how many times to expand the display range in the true motion mode. 1.3R (R = Range) and 1.6R are available and the default setting is 1.6R.

BEARING REF: Selects how to reference bearing for the vertical bearing marker. The choices are ship’s heading (default) and North.

TILT LEVER: Chooses function of the TILT control.

TILT:

Sets the tilt only.

TILT & V1:

Sets the bearing of the vertical 1 display in the vertical display, and

 

sets the tilt in the horizontal display.

S AUTO OFF CENTER: Choose the train value in automatic own ship position offset in the slant mode. The choices are 30°, 45°, 60° and OFF and the default setting is 45°. AUTO TRAIN must be turned on to activate this function.

H-SLICE WIDTH: Chooses width of the history marker in the history display. The choices are 1, 2, 4 and 8, 16 (default setting) and 32. The higher the number the greater the width.

H-SLICE PICT ADVC: Determines how to advance the history display, by KP SYNC (default setting) or ship’s speed.

NET COURSE MARK: Inscribes/deletes the net course mark. For further details see “2.19 Net Course Mark”.

MANUAL DEGAUSS: In the default setting the screen is automatically degaussed by the internal sensor when it detects stray magnetic fields on the screen. If you want to degauss the screen manually select MANUAL DEGAUSS and press the [MENU] key. Execute degaussing in intervals; consecutive degaussing may result in color distortion.

AUTO DEGAUSS: Selects how to degauss the screen automatically. OFF: Turns automatic degaussing off.

TIMER: Degausses at regular intervals.

GYRO: Using heading data from a heading sensor, degaussing occurs when heading change exceeds a certain value.

INT SENSOR: Degaussing occurs when the sensor in the monitor unit detects heading change which exceeds a certain value. This option is only operative on the FURUNO monitor unit FSV-2400.

DIMMER: Adjusts backlighting of the control panel. The setting range is 1-10 and the default setting is 10 (maximum).

KEY BEEP VOLUME: Sets the volume of the beep which sounds for key operation. The setting range is 0-7. “0” turns off the key beep.

9-3

Page 197
Image 197
Furuno FSV-84 manual Tilt