2. HORIZONTAL MODE

2.10Adjusting Beamwidth

The horizontal beamwidth of the Rx beam can be adjusted at the OTHERS menu as below to raise the horizontal resolution.

1.Press the [MENU] key to open the menu.

2.Select H-SCAN SETTING and press the [MENU] key.

3.Select OTHERS and press the [MENU] key.

MENU

 

QUIT

 

 

 

 

H-SCAN SETTING

 

QUIT

 

 

 

OTHERS

 

QUIT

COLOR

: COLOR 1

COLOR SETTING...

 

 

COLOR RESPONSE

: COLOR CURVE 3

COLOR RESPONSE...

 

 

GAIN OFFSET

: 0

 

SIGNAL LEVEL

: 0

 

FAR TVG CURVE

: TVG2

ABSORPTION COEFF : 23.5dB

TVG DISTANCE...

 

 

2ND AGC DISTANCE

: 0m

NEAR AGC DISTANCE: 200m

SMOOTH ECHO RNG : 0

SMOOTH ECHO CIR

: 0

 

GAIN CONTROL

: NORMAL

BEAMWIDTH...

 

 

 

 

 

.OTHERS menu

4. Select BEAMWIDTH and press the [MENU] key to open the dialog box.

MENU

 

QUIT

 

 

 

 

H-SCAN SETTING

 

QUIT

 

 

 

OTHERS

 

QUIT

 

 

 

BEAMWIDTH

 

QUIT

 

 

 

BEAMWIDTH A

: 0

 

BEAMWIDTH B

: 0

 

 

 

 

5.Select BEAMWIDTH A and set appropriate value. The higher the setting the sharper the horizontal resolution. The setting range is -4 to 5 plus AR and the default setting is 0. AR means AUTO RANGE and it automatically adjusts horizontal beamwidth according to the range.

6.Select BEAMWIDTH B and set appropriate value. This controls echo beam width by echo processing. The setting range is 0-5, and the higher the setting the greater the horizontal resolution.

7.Select QUIT and press the [MENU] key.

8.Select QUIT at the top of the menu screen and press the [MENU] key to close all menus.

2-25

Page 59
Image 59
Furuno FSV-84 manual Adjusting Beamwidth, Others menu