2. HORIZONTAL MODE

2.11.4TARGET LOCK menu

MENU

 

QUIT

OTHERS

 

QUIT

INITIAL SETTING

QUIT

TARGET LOCK

QUIT

TRACKING METHOD

 

: FISH

TILT INTERLOCK

 

: TILT&RANGE

MARK INTERLOCK

: ESTIMATE MARK

TRACKING DATA

 

: H&V

THRESHOLD

 

: 16

BOTTOM THRESHOLD

: 3

TARGET SPEED LIMIT

: 5kt

SMOOTHING

 

: 0.5

TARGET SPD UPDATE

: 60SEC

TARGET LOCK WINDOW

: NORMAL

DIMENSION SETUP

 

: 25t/1000m2

VOLUME SETUP

 

: 25t/1000m3

TARGET LOCK menu

TRACKING METHOD: Selects tracking method, target mark (position) or fish.

TILT INTERLOCK: Provides automatic change of tilt angle and range or tilt angle during target lock.

MARK INTERLOCK: Selects items of numeric/graphic data display during target lock operation.

TRACKING DATA: Selects which tracking data to use; horizontal, or both horizontal and vertical.

THRESHOLD: Selects the weakest echo color number to track. The setting range is 1 to 30.

BOTTOM THRESHOLD: When a target is judged as a bottom echo, raise this setting to differentiate bottom from target. The setting range is 0 to 5. The setting range is 0 to 5.

TARGET SPEED LIMIT: Sets maximum fish speed to track. The setting range is 1kt to 15kt.

SMOOTHING: Sets smoothing rate for fish speed data. The setting range is 0.0 to 1.0.

TARGET SPD UPDATE: Sets fish speed data update interval among 15, 30, 45 and 60 seconds.

TARGET LOCK WINDOW: Selects size of target lock detection area; normal, large, largest. However, this area is not displayed on the screen.

DIMENSION SETUP: Sets dimension constant for calculation of fish school tonnage from the fish school dimension.

VOLUME SETUP: Sets volume constant for calculation fish school tonnage from fish school volume.

2-29

Page 63
Image 63
Furuno FSV-84 manual Target Lock menu