11. MAINTENANCE, TROUBLESHOOTING

11.5Warning Messages

The table below shows the warning messages which may appear on the display. All warning messages are accompanied by an audio alarm, which you may silence with the [R/B AUDIO] key.

Error messages

 

 

Message

Meaning, Remedy

 

 

 

 

Power supply

 

 

OVERVOLTAGE!!

This message blinks at the screen center and

RETRACT TRANSDUCER AND TURN OFF

the buzzer sounds when the voltage supplied

POWER. CHECK SHIP’S MAINS VOLTAGE.

to the transceiver unit is excessive.

PRESS [R/B] KEY TO TURN OFF ALARM.

Transmission is stopped if the equipment is

 

 

 

transmitting, to protect the transducer and

 

 

 

transmitter power section from damage.

 

 

 

Silence the buzzer with the [R/B AUDIO] key,

 

 

 

retract the transducer and turn off the power.

 

 

 

Have a qualified technician check input

 

 

 

voltage.

Transceiver unit

 

 

NO RESPONSE FROM TRANSCEIVER

This message blinks at the screen center and

UNIT.

the buzzer sounds when there is no reply

TURN OFF AND ON POWER AGAIN, OR

from the transceiver unit. Press the [R/B

CHECK POWER LINE TO TRANSCEIVER

AUDIO] key to turn off the buzzer. Have a

UNIT. PRESS [R/B] KEY TO TURN OFF

qualified technician check the set.

ALARM.

 

ELECTRIC CHARGE!!

This message blinks at the screen center and

RETRACT TRANSDUCER AND TURN OFF

the buzzer sounds if the +B voltage of

POWER. CHECK SHIP’S MAINS VOLTAGE.

capacitors in the transceiver unit can not be

PRESS R/B KEY TO TURN OFF ALARM.

charged to predetermined voltage within the

 

 

 

specified time. Press the [R/B AUDIO] key to

 

 

 

silence the buzzer. Have a qualified

 

 

 

technician check the set.

OVER TEMPERATURE!!

This message blinks at the screen center and

RETRACT TRANSDUCER AND TURN OFF

the buzzer sounds when the temperature in

POWER.

the power supply block has exceeded 85°C.

PRESS R-B KEY TO TURN OFF ALARM.

Press the [R/B AUDIO] key to silence the

 

 

 

buzzer. Turn off the unit and have a qualified

 

 

 

technician check the set.

Hull unit

, transducer

 

TRANSDUCER NOT RETRACTED!!

This message blinks at the screen center, the

CUT OFF POWER LINE TO MONITOR UNIT

buzzer sounds and the LEDs above keys

AND HULL UNIT. PRESS [R/B] KEY TO

blink if the transducer is not raised within 26

TURN OFF ALARM.

seconds for 800 mm stroke or 33 seconds for

 

 

 

1100 mm stroke of pressing the [↑] key.

 

 

 

Press the [R/B AUDIO] key to silence the

 

 

 

buzzer. The reason may be the transducer is

 

 

 

tangled in the net or its shaft is bent. Try

 

 

 

raising it from the hull unit as shown in

 

 

 

section 11.9.