Section 4. Electric Checks and Adjustments
4.10 Ribbon Sensor Adjustment
Additional equipment required: TP Test Module
Digital Multimeter
STEP PROCEDURE
Refer to Section 4.2 for access to main PCB
1.Turn VR4 potentiometer on the main PCB all the way to the right.
2.Refer to Section 4.3.
Set the digital multimeter to DC voltage measurement mode.
Attach the connector from the TP Test Module to the test port on the main PCB. Note correct positioning of connector. Set the dial to 7.
3.Connect (+) probe of the multimeter to Sig+ and
4.Refer to Section
5.For High level adjustment, rotate the ribbon unwind shaft to align one of the "tabs" with the sensor. Check the electrical level. If the level difference is + 2.3 V more than the Low level, it is acceptable. If not, return to STEP 4 and readjust.
6. | Standard values: | Low level (slot): +1.0 V or less. | |
|
| High level (tab): Low level +2.3 V or higher | |
| NOTE: Adjust low level to achieve the biggest difference between each level | ||
| by repeating the process If these values do not result, try the following: | ||
|
| a) | Repeat the process |
|
| b) | Clean the sensor |
|
| c) | Replace the sensor |
Page | SATO CL608e/CL612e Service Manual |