Section

Configuration

2

 

 

 

 

2.1 Dip Switch Settings

Two DIP switches (DSW2 & DSW3) are located inside the Front Access Door. These switches can be used to set:

Thermal transfer or direct thermal mode

Head Check Mode

Hex Dump Mode

Label sensor enable/disable

Single Job or Multi-Job Receive Buffer

Operation Mode

DIP SWITCHES

In addition, a third DIP switch (DSW1) is located on the optional RS232 Serial Adapter card and is used to set the RS232C transmit/receive parameters.

DSW1

Each switch is an eight section toggle switch. The On position is always to the top. To set the switches, first power the unit Off, then position the DIP switches. Finally after placing the switches in the desired positions, power the printer back on. The switch settings are read by the printer electronics during the power-up sequence. They will not become effect until the power is cycled.

PN 9001079

SATO CL608e/CL612e Service Manual

Page 2-1

Rev. B

 

 

Page 23
Image 23
SATO CL608e/CL612e manual Dip Switch Settings, DSW1