Section 2. Configuration

Dip Switch Settings

External Signal Type Selection (DSW3-6, DSW3-7): Both the polarity and signal type (level or pulse) of the external print synchronizing signal can be selected. See Section 3 for a definition of signal types.

DSW3-6

DSW3-7

SETTING

 

 

 

 

DSW3

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

Off

Off

Type 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

On

Type 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

 

8

 

 

 

 

On

Off

Type 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On

On

Type 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Repeat Print via External Signal(DSW3-8):Allows an applicator or other device to

reprint the last label of the print job. See Section 3: Interface Specifications for a description of the signal requirements.

DSW3-8

SETTING

 

 

Off

Disabled

 

 

On

Enabled

 

 

DSW3

ON

OFF

1 2 3 4 5 6 7 8

Page 2-6

SATO CL608e/CL612e Service Manual

PN 9001079 Rev.B

Page 28
Image 28
SATO CL608e/CL612e manual Setting DSW3