Section 4. Electric Checks and Adjustments

4.8 Offset Label Stop Position Adjustment

Used for fine adjustment of label stop position for Tear Off, Cutter and Dispense Modes. The Label Stop Position is adjusted with the Offset potentiometer on the Front Panel.

VR 2

POTENTIOMETERS ARE LOCATED UNDERNEATH A FLIP - DOWN COVER OF THE FRONT PANEL

Note: The stop position only is changed with the VR2 (OFFSET). The print position is changed with the VR3(PITCH).

The VR2(OFFSET) adjustment range is +/- 3.75mm.

STEP PROCEDURE

1.Flip down the cover on the front panel for access to the potentiometers.

2.TurnVR2(OFFSET) to the center position.

3.Press the FEED key while simultaneously turning ON the power switch.

4.When the printer beeps, release the key The following screens will appear.

initializing

rom v00.00.00.00

test print mode configuration

5.Press the FEED key to display the next screen.

test print size 10cm

6.Use the LINE Key to step to the second digit of the counter to the desired setting. The display will increment one step each time the LINE key is pressed. After the reading will advances to a setting of 09, it will automatically wrap and start at 10 CM again.

7.Press the FEED key for a test print. Press the FEED key again to stop printing.

press feed key to stop printing

8.Adjust the stop position using VR2 and feed another label. When the adjustment is correct, turn the printer off. If the print position can't be adjusted replace the Keyboard PCB. Refer to Section 6.

Page 4-12

SATO CL608e/CL612e Service Manual

PN 9001079 Rev. B

Page 88
Image 88
SATO CL608e/CL612e manual Initializing Rom, Offset Label Stop Position Adjustment