Section 4. Electric Checks and Adjustments

DC Power Voltage Checks

LCD DISPLAY

CABLE TO PCB

PROBES

DIAL

COM

GROUND SIG PIN

 

VOLT

 

 

PIN

 

 

 

 

TP TEST MODULE

 

DIGITAL

 

 

 

 

MULTIMETER

 

 

 

 

 

 

Dial POS

DISC

VOLTAGE RANGE

TP TEST MODULE

 

 

 

 

 

 

 

SG

 

 

 

 

 

 

 

 

 

NC

 

 

 

 

 

 

 

 

0

+5V

+4.8 to +5.2V

CHA3 (+5V) - CHA1 (GND)

 

 

 

 

 

 

1

+2.0V

+1.90 to +2.1V

CHA4 (+2.0V) - CHA1 (GND)

 

 

 

 

 

 

2

+3.3V

+3.1V to +3.5V

CHA5 (+3.3V) - CHA1 (GND)

 

 

 

 

 

 

3

+24V

+23.5V to +24.5V

CHA6 (+24V) - CHA1 (GND)

 

 

 

 

 

GND

A1

+5V

+2.0V

+3.3V

+24V

A6

TEST POINT CHART

B1

NOTE: The power supply voltages are not adjustable. All voltages must read within +/- 10% of the nominal value for correct operation of the printer.

B6

PN 9001079

SATO CL608e/CL612e Service Manual

Page 4-5

Rev. B

 

 

Page 81
Image 81
SATO CL608e/CL612e manual TP Test Module, Test Point Chart