| Section | |
Electrical Checks and Adjustments |
| " |
4.1 Overview
This chapter describes how to check CL608e/CL612e Printers voltage levels and adjust threshold sensor voltages.
The power supply converts 125 VAC into regulated DC voltages. The printer uses: +5V and +24V These DC voltages are not adjustable, however you can measure these DC voltages at test points located on the PCB. Section
You can adjust threshold voltage levels for label sensors. These adjustments are made to allow for variations in the characteristics of the labels used with the printer. If you cannot calibrate the label sensor voltage level within the specified voltage range, you should reposition the label sensor by following the adjustment procedures included in this section. After completing the label sensor adjustment procedures, perform the label sensor voltage level adjustment procedure.
You can check or adjust:
•Power Supply
•Label Sensors
•Ribbon Sensor
•Pitch Offset
•Label Positions
Checks and adjustments in this section require standard metric tools. Also required:
Digital Multimeter required for use with SATO TP Test Module (Voltage Checker) Part # RH1773100 and is required for most electrical adjustments.
PN 9001079 | SATO CL608e/CL612e Service Manual | Page |
Rev. B |
|
|