Section 4. Electric Checks and Adjustments

4.5b Print Position Adjustment

Using VR1 potentiometer on the main PCB board.

STEP PROCEDURE

VR1 adjustment range is +/- 3.75mm.

Refer to Section 4.2 for access to main PCB

1.Record all current dip switch positions, then place all switches in the OFF position and the power switch OFF.

2.Turn VR1 on the main PC Board to the center position.

3.Place DSW2-4 in the ON (up) position.

4.Press the LINE and FEED key while simultaneously turning the power switch ON.

5.When the printer beeps, release the keys. The following screens will appear.

initializing

rom v00.00.00.00

maintentance mode dipsw2-4 on->Off

6.Place DSW2-4 in the OFF (down) position and the screen will display the next screen.

factory mode

7.Press the FEED key to display the next screen.

counter clear none

8.Confirm "None" then press the FEED key to display the next screen.

The default is Large.

print size small large

9.Press the FEED key for a test print. Press the FEED key again to stop

printing.

test print

press the feed key

10.Adjust the position using the VR1 potentiometer and feed another label. When the adjustment is correct, turn the printer off. If the print position can't be adjusted with the VR1, replace the Main PCB. Refer to Section 6.

PN 9001079

SATO CL608e/CL612e Service Manual

Page 4-9

Rev. B

 

 

Page 85
Image 85
SATO CL608e/CL612e manual Test print Press the feed key, 5b Print Position Adjustment