SATO CL608e/CL612e manual DC Power Voltage Checks, Power Supply Main PCB Interface Board VR2 DEM

Models: CL608e/CL612e

1 245
Download 245 pages 38.96 Kb
Page 79
Image 79

Section 4. Electric Checks and Adjustments

4.3 DC Power Voltage Checks

To check voltage levels, first check the fuses (Section 6.3) and replace if necessary Then remove the LH cover, (Section 4.2) and perform the following steps.

Addtional equipment required: TP Test Module

Digital Multimeter

STEP

PROCEDURE

Refer to illustrations on pages 4-3 through 4-5.

1.Attach the connector from the TP Test Module to the test port on the main PCB. Note correct positioning of connector. Nibs on the connector are placed down in the receptacle on the PCB in the forward position.

2.Attach the ground probe of the multimeter to the TP Test Module Gnd pin.

3.Attach the positive probe of the multimeter to the +SIG pin on the TP Test Module terminal.

4.Turn printer on and rotate the dial to a dial POS on the TP Test Module. Record the values from the Multimeter LCD.

5.Confirm voltages are correct. If not, then replace power supply Refer to Section 6.4.

6.After performing tests, replace the LH cover to the printer.

POWER SUPPLY

MAIN PCB

INTERFACE

BOARD

VR2 DEM

VR3 CE

 

VR5 IM

VR4 GAP VR1 OFS

TEST POINT CONNECTOR

CN13

PN 9001079

SATO CL608e/CL612e Service Manual

Page 4-3

Rev. B

 

 

Page 79
Image 79
SATO CL608e/CL612e manual DC Power Voltage Checks, Power Supply Main PCB Interface Board VR2 DEM, Test Point Connector