Section 3. Interface Specifications
3.3 The Receive Buffer
The CL608e/CL612e printers have the ability to receive a data stream from the host in one of two ways. The receive buffer may be configured to accept one print job at a time or multiple print jobs. The single job print buffer is generally used by software programs that wish to maintain control of the job print queue so that it can move a high priority job in front of ones of lesser importance. The multiple job buffer on the other hand prints all jobs in the order they are received by the printer and the order of printing cannot be changed.
Single Job Buffer
The printer receives and prints one job at a time. Each job must not exceed 2.95MB.
Multi Job Buffer
The printer is able to continuously receive print jobs, compiling and printing other jobs at the same time. It acts much like a "print buffer" ot maximize the performance of the host and the printer.
When using the RS232 Serial interface, the Multi Job Buffer uses either the Ready/ Busy with DTR (pin 20) or
0 | 2.0 MB | 2.95MB | |||
|
|
|
| ||
|
|
|
|
|
|
DTR High
or
Buffer Near Full
or
The receiving buffer will not be able to receive more data again until a "Buffer Available" condition occurs. This takes place when the receiving buffer has emptied so that only 1MB bytes of data are being held (2.0MB bytes from being full). At this time, DTR will go "high" or an
PN 9001079 | SATO CL608e/CL612e Service Manual | Page |
Rev. B |
|
|