Probable cause | Solution |
|
|
The surge protector or | Disconnect the monitor power cable, then connect it directly |
UPS is damaged | to the power source. |
|
|
The monitor is too close | Move the monitor away from sources of electrical |
to a source of electrical | interference, such as televisions, unshielded speakers, |
interference | microwave ovens, fluorescent lights, and metal beams or |
| shelves. |
|
|
The monitor needs to be | Turn off the server and monitor and leave them off for at least |
degaussed | a half hour, then restart the system. |
|
|
Error codes and test points
This section lists test points and beep codes that you may encounter. These codes often indicate procedural errors such as an incorrect keystroke or a
Test | Beep POST Routine Description | |
Point | Code | |
|
|
|
02h |
| Verify real mode |
|
|
|
03h |
| Disable |
|
|
|
04h |
| Get processor type |
|
|
|
06h |
| Initialize system hardware |
|
|
|
07h |
| Disable shadow and execute code from ROM |
|
|
|
08h |
| Initialize chipset with initial POST values |
|
|
|
09h |
| Set IN POST flag |
|
|
|
0Ah |
| Initialize processor registers |
|
|
|
0Bh |
| Enable processor cache |
|
|
|
0Ch |
| Initialize caches to initial POST values |
|
|
|
0Eh |
| Initialize I/O components |
|
|
|
0Fh |
| Initialize the local bus IDE |
|
|
|
10h |
| Initialize power management |
|
|
|
11h |
| Load alternate registers with initial POST values |
|
|
|
*If the BIOS detects error 2C or 2E, it displays an additional
88Gateway 7450R Server System Manual