Hitachi CP-X200 instruction manual -60, 60, Network Communications Settings

Models: CP-X200

1 305
Download 305 pages 53.24 Kb
Page 143
Image 143

360

360

Network Communications Settings

The following table lists parameters that configure the inverter’s serial communications port. The settings affect how the inverter communication with a digital operator (such as SRW-0EX), as well as a ModBus network (for networked inverter applications). The settings cannot be edited via the network, in order to ensure network reliability. Refer to “ModBus Network Communications” on page B-1for more information on controlling any monitoring your inverter from a network.

 

 

 

“C” Function

Run

Defaults

 

Func.

Name /

 

Description

Mode -FE -FU

Units

 

Code

SRW Display

 

Edit (EU)

 

(USA)

 

 

 

 

C070

Selection of OPE / ModBus

Two option codes:

 

02

 

02



 

 

 

 

02

OPE or option

 

 

 

 

 

 

 

PARAM

REM

03

ModBus (485)

 

 

 

 

 

 

C071

Communication speed

Three option codes:

 

06

 

04

baud

 

 

selection

 

04

4800 bps

 

 

 

 

 

 

 

 

 

05

9600 bps

 

 

 

 

 

&RQ¿JXULQJ'ULYH Parameters

 

COM BAU

4800

06

19200 bps

 

 

 

 

 

C072

Node allocation

 

02

Odd parity

 

1.

 

1.

 

 

 

Set the address of the inverter on

 

 



 

 

COM ADR

00001

the network. Range is 1 to 32

 

 

 

 

 

 

C074

Communication parity

Three option codes:

 

00

 

00



 

 

selection

 

00

No parity

 

 

 

 

 

 

 

 

 

01

Even parity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM PRTY

NON

 

 

 

 

 

 

 

 

C075

Communication stop bit

Range is 1 to 2

 

1

 

1

bit

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM STP

1BIT

 

 

 

 

 

 

 

 

C076

Communication error select

Selects inverter response to

 

02

 

02



 

 

 

 

communications error.

 

 

 

 

 

 

 

 

 

Five options:

 

 

 

 

 

 

 

 

 

00

Trip (Error code E60)

 

 

 

 

 

 

 

 

 

01

Decelerate to a stop and trip

 

 

 

 

 

 

 

 

 

 

(Error code E60)

 

 

 

 

 

 

 

 

 

02

Disable

 

 

 

 

 

 

 

 

 

03

Free run stop (coasting)

 

 

 

 

 

 

 

COM ESlct

None

04

Decelerate to a stop

 

 

 

 

 

 

C077

Communication error time-

Sets the communications watchdog

 

0.00

 

0.00

sec.

 

 

out

 

timer period.

 

 

 

 

 

 

 

COM ETIM

000.00s

Range is 0.00 to 99.99 sec

 

 

 

 

 

 

C078

Communication wait time

Time the inverter waits after

 

0.

 

0.

msec.

 

 

 

 

receiving a message before it

 

 

 

 

 

 

 

 

 

transmits.

 

 

 

 

 

 

 

COM Wait

00000ms

Range is 0. to 1000. ms

 

 

 

 

 

Parameters

Configuring Drive

Page 143
Image 143
Hitachi CP-X200 instruction manual -60, 60, Network Communications Settings

CP-X200 specifications

The Hitachi CP-X200 is a versatile and robust projector designed to cater to the needs of educational and business environments. It combines affordability with high-quality performance, making it an attractive option for various presentations and multimedia applications.

At the heart of the CP-X200 is its high brightness capability, with a lumen output of 3,000 ANSI lumens. This feature enables the projector to deliver clear and vibrant images even in well-lit rooms. The resolution of XGA (1024 x 768 pixels) ensures that text and graphics are sharp, making it suitable for everything from classroom lectures to corporate presentations.

One of the standout characteristics of the Hitachi CP-X200 is its advanced lamp technology. The projector uses a long-lasting lamp that can provide up to 5,000 hours of usage in standard mode, allowing for extended intervals between lamp replacements. Additionally, the ECO mode can further enhance the lamp life, extending its longevity while reducing energy consumption.

The CP-X200 is equipped with a variety of connectivity options, including HDMI, VGA, and composite inputs, allowing users to easily connect it to various devices such as laptops, DVD players, and other multimedia systems. The inclusion of USB and RS-232 interfaces ensures compatibility with different control systems, making it a flexible choice for diverse setups.

Another significant feature is the projector's built-in 10-watt speaker, which provides decent audio output, eliminating the need for external speakers in smaller venues. The speaker system enhances presentations, ensuring that audio and visuals are cohesive, promoting better audience engagement.

Portability is another key aspect of the Hitachi CP-X200, which weighs just around 3.5 kg (approximately 7.7 lbs), allowing for easy transport between locations. Its compact design makes it suitable for both fixed installations and mobile use, catering to professionals who require a projector that adapts to various environments.

The user-friendly interface and robust remote control enhance the projector's operability, providing easy access to essential functions. Additionally, features such as auto keystone correction adjust the image to maintain consistent quality even when the projector is not perfectly aligned with the screen.

In summary, the Hitachi CP-X200 is a feature-rich projector that embodies reliability, performance, and ease of use. Its combination of high brightness, various connectivity options, long lamp life, portability, and integrated audio makes it an excellent choice for education and business professionals seeking a dependable presentation solution.