Configuring Drive

Parameters

 

 

355

355

Output Function Summary Table – This table shows all twelve functions for the logical outputs (terminals [11] and [AL]) at a glance. Detailed descriptions of these functions, related parameters and settings, and example wiring diagrams are in “Using Intelligent Output Terminals” on page 4-34.

Option

Terminal

Output Function Summary Table

 

Function Name

 

Description

 

Code

Symbol

 

 

 

 

 

 

00

RUN

Run Signal

ON

When the inverter is in Run Mode

 

 

 

 

OFF

When the inverter is in Stop Mode

 

01

FA1

Frequency Arrival Type

ON

When output to motor is at the set frequency

 

 

 

1–Constant Speed

OFF

When output to motor is OFF, or in any

 

 

 

 

 

acceleration or deceleration ramp

 

02

FA2

Frequency Arrival Type

ON

When output to motor is at or above the set

 

 

 

2–Over frequency

 

frequency, even if in accel. or decel rams

 

 

 

 

OFF

When output to motor is OFF, or at a level

 

 

 

 

 

below the set frequency

 

03

OL

Overload Advance

ON

When output current is more than the set

 

 

 

Notice Signal

 

threshold for the overload signal

 

 

 

 

OFF

When output current is less than the set

&RQ¿JXULQJ'ULYH Parameters

 

 

 

 

been cleared

 

 

 

 

threshold for the deviation signal

 

04

OD

Output Deviation for

ON

When PID error is more than the set threshold

 

 

 

PID Control

 

for the deviation signal

 

 

 

 

OFF

When PID error is less than the set threshold

 

 

 

 

 

for the deviation signal

 

05

AL

Alarm Signal

ON

When an alarm signal has occurred and has not

 

 

 

 

OFF

When no alarm has occurred since the last

 

 

 

 

 

cleaning of alarm(s)

 

06

Dc

Analog Input

ON

When the [O] input value < B082 setting (signal

 

 

 

Disconnect Detect

 

loss detected), or the [OI] input current < 4mA

 

 

 

 

OFF

When no signal loss is detected

 

07

FBV

PID Second Stage

ON

Transitions to ON when the inverter is in RUN

 

 

 

Output

 

Mode and the PID Process Variable (PV) is less

 

 

 

 

 

than the Feedback Low Limit (C053)

 

 

 

 

OFF

Transitions to OFF when the PID Process

 

 

 

 

 

Variable (PV) exceeds the PID High Limit

 

 

 

 

 

(C052), and transitions to OFF when the

 

 

 

 

 

inverter goes from Run Mode to Stop Mode

 

08

NDc

Network Detection

ON

When the communications watchdog timer

 

 

 

Signal

 

(period specified by C077) has time out

 

 

 

 

OFF

When the communications watchdog timer is

 

 

 

 

 

satisfied by regular communications activity

 

09

LOG

Logic Output Function

ON

When the Boolean operation specified by C143

 

 

 

 

 

has a logical “1” result

 

 

 

 

OFF

When the Boolean operation specified by C143

 

 

 

 

 

has a logical “0” result

 

10

ODc

Communication option

ON

No communication between communication

 

 

 

error

 

option is detected during a time set in P044

 

 

 

 

OFF

Communication is normal

 

43

LOC

Low load detection

ON

Motor current is less than the set value of C039

 

 

 

 

OFF

Motor current is not less than the set value of

 

 

 

 

 

C039

 

Page 138
Image 138
Hitachi CP-X200 instruction manual -55, 55

CP-X200 specifications

The Hitachi CP-X200 is a versatile and robust projector designed to cater to the needs of educational and business environments. It combines affordability with high-quality performance, making it an attractive option for various presentations and multimedia applications.

At the heart of the CP-X200 is its high brightness capability, with a lumen output of 3,000 ANSI lumens. This feature enables the projector to deliver clear and vibrant images even in well-lit rooms. The resolution of XGA (1024 x 768 pixels) ensures that text and graphics are sharp, making it suitable for everything from classroom lectures to corporate presentations.

One of the standout characteristics of the Hitachi CP-X200 is its advanced lamp technology. The projector uses a long-lasting lamp that can provide up to 5,000 hours of usage in standard mode, allowing for extended intervals between lamp replacements. Additionally, the ECO mode can further enhance the lamp life, extending its longevity while reducing energy consumption.

The CP-X200 is equipped with a variety of connectivity options, including HDMI, VGA, and composite inputs, allowing users to easily connect it to various devices such as laptops, DVD players, and other multimedia systems. The inclusion of USB and RS-232 interfaces ensures compatibility with different control systems, making it a flexible choice for diverse setups.

Another significant feature is the projector's built-in 10-watt speaker, which provides decent audio output, eliminating the need for external speakers in smaller venues. The speaker system enhances presentations, ensuring that audio and visuals are cohesive, promoting better audience engagement.

Portability is another key aspect of the Hitachi CP-X200, which weighs just around 3.5 kg (approximately 7.7 lbs), allowing for easy transport between locations. Its compact design makes it suitable for both fixed installations and mobile use, catering to professionals who require a projector that adapts to various environments.

The user-friendly interface and robust remote control enhance the projector's operability, providing easy access to essential functions. Additionally, features such as auto keystone correction adjust the image to maintain consistent quality even when the projector is not perfectly aligned with the screen.

In summary, the Hitachi CP-X200 is a feature-rich projector that embodies reliability, performance, and ease of use. Its combination of high brightness, various connectivity options, long lamp life, portability, and integrated audio makes it an excellent choice for education and business professionals seeking a dependable presentation solution.