Set Second Motor, Special Set

andOperations Monitoring

Monitoring

and

 

Operations

 

 

 

 

 

If you assign the [SET] function to an intelligent input terminal, you can select between two sets of motor parameters. The second parameters store an alternate set of motor characteristics. When the terminal [SET] is turned ON, the inverter will use the second set of parameters to generate the frequency output to the motor. When changing the state of the [SET] input terminal, the change will not take effect until the inverter is stopped. Special Set [SP-SET] is for changing the second motor parameters without stopping the motor. However the changeable parameters are limited.

When you turn ON the [SET] input, the inverter operates per the second set of parameters. When the terminal is turned OFF, the output function returns to the original settings (first set of motor parameters). Refer to “Configuring the Inverter for Multiple Motors” on page 4–58for details.

 

Parameters

SET

SP-SET

Parameters

SET

SP-SET

 

F002/F202

9

9

A093/A293

9

9

 

F003/F203

9

9

A094/A294

9

9

 

A001/A201

9

-

A095/A295

9

9

 

A002/A202

9

-

A096/A296

9

9

 

A003/A203

9

-

b012/b212

9

-

 

A004/A204

9

-

b013/b213

9

-

 

A020/A220

9

9

b021/b221

9

-

 

A041/A241

9

-

b022/b222

9

-

 

A042/A242

9

9

b023/b223

9

-

 

A043/A243

9

9

b028/b228

9

-

 

A044/A244

9

-

C001~C005/

9

-

 

A045/A245

9

-

C201~C205

 

 

 

 

A061/A261

9

9

C041/C241

9

-

 

A062/A262

9

9

H003/H203

9

-

 

A092/A292

9

9

H004/H204

9

-

 

 

 

 

H006/H206

9

-

Option

Terminal

Function Name

State

 

 

Description

Code

Symbol

 

 

 

 

 

 

 

 

08

SET

Set (select) 2nd

ON

causes the inverter to use the 2nd set of motor

 

 

Motor data

 

 

parameters for generating the frequency output to

53

SP-SET

Set 2nd motor data

 

motor

 

 

OFF

causes the inverter to use the 1st (main) set of

 

 

Special SET

 

 

motor parameters for generating the frequency

Valid for inputs:

C001~C005

 

 

output to motor

 

 

 

Example (requires input configuration—see

Required settings

(none)

 

 

page 3–49):

 

 

Notes:

 

 

 

 

 

 

SET / SP-SET

ξ If the terminal state is changed while the

 

 

5

4 3 2 1 L PCS P24

inverter is running, the inverter continues using

 

the current set of parameters until the inverter

 

 

 

is stopped.

 

 

 

 

 

 

See I/O specs on page 4–6.