Hitachi CP-X200 instruction manual Viii

Models: CP-X200

1 305
Download 305 pages 53.24 Kb
Page 9
Image 9

viii viii

Warnings for Configuring Drive Parameters

WARNING: When parameter B012, level of electronic thermal setting, is set to motor FLA rating (Full Load Ampere nameplate rating), the inverter provides solid state motor overload protection at 115% of motor FLA or equivalent. If parameter B012 exceeds the motor FLA rating, the motor may overheat and damaged. Parameter B012, level of electronic thermal setting, is a variable parameter.

3-34

Cautions for Configuring Drive Parameters

CAUTION: Be careful to avoid specifying a braking time that is long enough to

3-19

cause motor overheating. If you use DC braking, we recommend using a motor with

 

a built-in thermistor, and wiring it to the inverter’s thermistor input (see

 

“Thermistor Thermal Protection” on page 4-24). Also refer to the motor

 

manufacturer’s specifications for duty-cycle recommendations during DC braking.

 

HIGH VOLTAGE: When set RDY function ON, there will be a voltage appear at

3-47

motor output terminals U, V and W even if the motor is in stop mode. So never

 

touch the inverter power terminal even the motor is not running.

 

CAUTION: Do not change Debug mode for safety reasons. Otherwise unexpected

3-62

performances may occur.

 

Warnings for Operations and Monitoring

WARNING: Be sure to turn ON the input power supply only after closing the front

4-3

case. While the inverter is energized, be sure not to open the front case. Otherwise,

 

there is the danger of electric shock.

 

WARNING: Be sure not to operate electrical equipment with wet hands. Otherwise,

4-3

there is the danger of electric shock.

 

WARNING: While the inverter is energized, be sure not to touch the inverter

4-3

terminals even when the motor is stopped. Otherwise, there is the danger of electric

 

shock.

 

WARNING: If the retry mode is selected, the motor may suddenly restart after a

4-3

trip stop. Be sure to stop the inverter before approaching the machine (be sure to

 

design the machine so that safety for personnel is secure even if it restarts.)

 

Otherwise, it may cause injury to personnel.

 

WARNING: If the power supply is cut OFF for a short period of time, the inverter

4-3

may restart operating after the power supply recovers if the Run command is

 

active. If a restart may pose danger to personnel, so be sure to use a lock-out circuit

 

so that it will not restart after power recovery. Otherwise, it may cause injury to

 

personnel.

 

WARNING: The Stop Key is effective only when the stop function is enabled. Be

4-3

sure to enable the Stop Key separately from the emergency stop. Otherwise, it may

 

cause injury to personnel.

 

WARNING: During a trip event, if the alarm reset is applied and the Run command

4-3

is present, the inverter will automatically restart. Be sure to apply the alarm reset

 

only after verifying the Run command is OFF. Otherwise, it may cause injury to

 

personnel.

 

Page 9
Image 9
Hitachi CP-X200 instruction manual Viii

CP-X200 specifications

The Hitachi CP-X200 is a versatile and robust projector designed to cater to the needs of educational and business environments. It combines affordability with high-quality performance, making it an attractive option for various presentations and multimedia applications.

At the heart of the CP-X200 is its high brightness capability, with a lumen output of 3,000 ANSI lumens. This feature enables the projector to deliver clear and vibrant images even in well-lit rooms. The resolution of XGA (1024 x 768 pixels) ensures that text and graphics are sharp, making it suitable for everything from classroom lectures to corporate presentations.

One of the standout characteristics of the Hitachi CP-X200 is its advanced lamp technology. The projector uses a long-lasting lamp that can provide up to 5,000 hours of usage in standard mode, allowing for extended intervals between lamp replacements. Additionally, the ECO mode can further enhance the lamp life, extending its longevity while reducing energy consumption.

The CP-X200 is equipped with a variety of connectivity options, including HDMI, VGA, and composite inputs, allowing users to easily connect it to various devices such as laptops, DVD players, and other multimedia systems. The inclusion of USB and RS-232 interfaces ensures compatibility with different control systems, making it a flexible choice for diverse setups.

Another significant feature is the projector's built-in 10-watt speaker, which provides decent audio output, eliminating the need for external speakers in smaller venues. The speaker system enhances presentations, ensuring that audio and visuals are cohesive, promoting better audience engagement.

Portability is another key aspect of the Hitachi CP-X200, which weighs just around 3.5 kg (approximately 7.7 lbs), allowing for easy transport between locations. Its compact design makes it suitable for both fixed installations and mobile use, catering to professionals who require a projector that adapts to various environments.

The user-friendly interface and robust remote control enhance the projector's operability, providing easy access to essential functions. Additionally, features such as auto keystone correction adjust the image to maintain consistent quality even when the projector is not perfectly aligned with the screen.

In summary, the Hitachi CP-X200 is a feature-rich projector that embodies reliability, performance, and ease of use. Its combination of high brightness, various connectivity options, long lamp life, portability, and integrated audio makes it an excellent choice for education and business professionals seeking a dependable presentation solution.