High-voltage power distribution

The high-voltage power supply PCA applies an overlap of DC and AC voltage to the primary charging roller and the developing roller. This circuit also applies a positive or negative DC voltage to the transfer roller according to the instructions from the ECU.

This circuit also controls the image density by changing the primary AC voltage and the developing AC bias according to the print density setting.

High voltage is disabled when SW101 is open (in other words, when the printer door is open).

Figure 10. High-voltage power supply circuit

EN

ECU/power system 71

Page 73
Image 73
HP 3150 manual High-voltage power distribution, High-voltage power supply circuit