Interface Access and System Information

System Information

For example, the time zone setting for Berlin, Germany is +60 (zone +1, or 60 minutes), and the time zone setting for Vancouver, Canada is -480 (zone -8, or -480 minutes). To configure the time zone and daylight time rule for Vancouver, Canada:

ProCurve(config)# time timezone -480 daylight-time-rule continental-us-and-canada

Configure the Time and Date. The switch uses the time command to con­ figure both the time of day and the date. Also, executing time without param­ eters lists the switch’s time of day and date. Note that the CLI uses a 24-hour clock scheme; that is, hour (hh) values from 1 p.m. to midnight are input as 13 - 24, respectively.

Syntax: time [ hh:mm [ :ss ]] [ mm/dd/ [ yy ] yy ]For example, to set the switch to 9:45 a.m. on November 17, 2002:ProCurve(config)# time 9:45 11/17/02

N o t e

Executing reload or boot resets the time and date to their default startup values.

Web: Configuring System ParametersIn the web browser interface, you can enter the following system information:System NameSystem LocationSystem Contact

For access to the MAC Age Interval and the Time parameters, use the menu interface or the CLI.

Configure System Parameters in the Web Browser Interface.1.Click on the Configuration tab.

2.Click on [System Info].

3.Enter the data you want in the displayed fields.4.Implement your new data by clicking on [Apply Changes].

To access the web-based help provided for the switch, click on [?] in the web browser screen.

7-18