Redundancy (Switches 8200zl)

 

Existing CLI Commands Affected by Redundant Management

 

 

Command

Action

 

 

 

 

reload <cr>

Boots (warm reboot) the active management module.

 

Switchover to the standby management module occurs if

 

redundancy is enabled. If redundancy is disabled or there is no

 

standby management module, the reload command boots the

 

system.

 

Note: If the running config file is different from the stored config

 

file, you will be prompted to save the config file. The reload

 

at/after versions of this command do not display a prompt to

 

save configuration file changes; the changes are lost on the

 

scheduled reload.

 

 

 

ProCurve(config)# reload

This command will cause a switchover to the other management module which may not be running the same software image and configurations. Do you want to continue [y/n]? y

(Boots….)

ProCurve(config)# show redundancy

Settings

--------

Mgmt Redundancy : Enabled

Statistics

----------

Failovers

: 1

 

 

 

Last Failover : Mon April 30 09:10:11 2007

 

 

 

Slot

Module Description

Status

SW Version Boot Image

----

----------------------------------------

--------

---------- ----------

1

ProCurve J9092A Management Module 8200zl

Active

K.12.XX

Primary

2

ProCurve J9092A Management Module 8200zl

Standby

K.12.XX

Primary

Figure 15-25. Example of Reload Command with Redundancy Enabled

15-33