Redundancy (Switches 8200zl)

 

Existing CLI Commands Affected by Redundant Management

 

 

Command

Action

 

 

fastboot

When fastboot is enabled, this information is saved to the standby

 

management module when the config files are sync’d. The fastboot

 

value is used during the next boot on both modules.

 

 

front-panel-security

This command and its options only affects the active management

factory-reset

module. See the section on “Front-Panel Button Functions” in the

password-clear

Access Security Guide for more information about resetting the

switch.

password-recovery

 

 

 

kill

Does not affect the console on the standby module.

 

 

log

Log messages from a formerly active management module are

 

available on the current active management module after a

 

switchover.

 

 

password (set or clear)

Affects only the active management module until a switchover

 

occurs, at which time it affects the new active module.

 

 

startup-default

Affects both modules. The config file is immediately sent to the

 

standby module and also becomes the default on that module when

 

the next boot occurs.

 

 

update

Only affects the active module. The standby may become the active

 

module when the updated active module is booted.

 

 

write

A write memory updates the config file in flash on the active

 

module. The file is then sync’d to the standby module.

 

 

15-35