Redundancy (Switches 8200zl)

Displaying Management Information

ProCurve(config)# show modules details

 

 

Status

and Counters - Module Information

 

 

Chassis: 8212zl J8715A

Serial Number:

SG560TN124

Status

Slot

Module Description

Serial Number

-----

----------------------------------------

--------------

-------

MM1

ProCurve J9092A

Management Module 8200zl

AD722BX88F

Active

SSM

ProCurve J8784A

System Support Module

AF988DC78G

Active

C

ProCurve J8750A

20p +4 Mini-GBIC Module

446S2BX007

Active

 

GBIC 1: J4859B

1GB LX-LC

4720347DFED734

 

 

GBIC 2: J4859B

1GB LX-LC

4720347DFED735

 

Figure 15-13. An Example of the show modules details Command for the 8212zl Showing SSM and Mini- GBIC Information

Show Redundancy

The show redundancy command displays information about the management and fabric modules. It displays the flash image last booted from, even if the boot set-defaultcommand has been set to change the flash booted from on the next boot.

ProCurve(config)# show redundancy

Settings

--------

Mgmt Redundancy : enabled

Statistics

----------

Failovers : 0 Last Failover :

The active management module was last booted from secondary flash. The standby management module was last booted from primary flash.

Slot

Module Description

Status

SW Version

Boot Image

----

----------------------------------------

--------

----------

----------

1

ProCurve

J9092A

Management Module 8200zl

Standby

K.12.XX

Primary

2

ProCurve

J9092A

Management Module 8200zl

Active

K.12.XX

Secondary

1ProCurve J9093A F2 Fabric Module 8200zl Enabled

2ProCurve J9093A F2 Fabric Module 8200zl Enabled

Figure 15-14. Example of show redundancy Command