Redundancy (Switches 8200zl)

Using Redundant Management

Enabling and Disabling Fabric Modules

The fabric modules can be enabled or disabled even if they are not present in the switch. You cannot disable both fabric modules at the same time; one must be enabled. Use this command to enable or disable the redundant fabric modules. Disabling one fabric module reduces the overall switching capacity of the 8200zl series switches. On some networks where network utilization is less than 50%, you may not notice any degradation of performance.

Syntax: redundancy fabric-module [1 2] [enable disable]

Allows enabling or disabling of fabric modules. You cannot have both fabric modules disabled at the same time. Default: Both fabric modules are enabled.

ProCurve(config)# redundancy fabric-module 2 disable

ProCurve(config)# show redundancy

Settings

--------

Mgmt Redundancy : enabled

Statistics

----------

Failovers : 0

Last Failover :

 

 

 

Slot

Module Description

Status

SW Version

Boot Image

----

----------------------------------------

--------

----------

----------

1

ProCurve

J9092A Management Module 8200zl

Active

K.12.XX

Primary

2

ProCurve

J9092A Management Module 8200zl

Standby

K.12.XX

Primary

1ProCurve J9093A F2 Fabric Module 8200zl Enabled

2ProCurve J9093A F2 Fabric Module 8200zl Disabled

Figure 15-7. Example of Disabling a Fabric Module

15-12