Power Over Ethernet (PoE/PoE+) Operation

Configuring PoE Operation

Manually Configuring PoE Power Levels

You can specify a power level (in watts) allocated for a port by using the value option. This is the maximum amount of power that will be delivered.

To configure a port by value, first set the PoE allocation by entering the poe­ allocate-by value command:

ProCurve(config)# int A6 poe-allocate-by valueor in interface context:ProCurve(eth-A6)# poe-allocate-by valueThen select a value:ProCurve(config)# int A6 poe-value 15

or in interface context:

ProCurve(eth-A6)# poe-value 15To view the settings, enter the show power-over-ethernetcommand:

ProCurve(config)# show power-over-ethernet A6

Status and Counters - Port Power Status for port A6

Power Enable

 

: Yes

 

 

 

 

 

 

 

 

 

 

LLDP Detect

 

 

: enabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Priority

 

 

 

 

 

 

:

low

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Configured

Type

 

:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15 W

 

AllocateBy

 

 

 

 

 

 

 

 

: value

 

 

 

 

 

 

 

 

 

 

Value

 

 

 

 

 

:

 

power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Detection Status

 

: Delivering

 

 

 

 

 

 

 

 

 

 

Power Class

: 2

 

 

 

 

 

 

delivered

Over Current Cnt

: 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MPS Absent Cnt

: 0

 

 

 

 

 

 

 

Power Denied Cnt

: 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short Cnt

: 0

 

 

 

 

 

 

 

Voltage

 

: 55.1 V

 

 

 

 

 

 

 

 

 

 

Current

 

 

: 154 mA

 

Power

 

: 8.4 W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 11-1. Example Displaying PoE Allocation by Value and the Maximum Power Delivered

If you set the PoE maximum value to less than the PD requires, a fault occurs.

11-13