Redundancy (Switches 8200zl)

Downloading a New Software Version

ProCurve(config)# show version

 

Management Module 1: Active

 

Image stamp:

/sw/code/build/btm(t2g)

 

 

Mar 15 2007 12:28:32

 

 

K.12.30

Mismatch exists

 

64

 

Boot Image:

Primary

 

Management Module 2: Standby

 

Image stamp:

/sw/code/build/btm(t2g)

 

 

Mar 21 2007 14:24:38

 

 

K.12.30

 

Boot Image:

789

 

Secondary

 

ProCurve(config)# show redundancy

 

Settings

 

 

--------

 

 

Mgmt Redundancy : Enabled

 

Statistics

 

 

----------

: 0

 

Failovers

 

Last Failover :

 

 

 

Slot

Module Description

Status

SW Version Boot Image

----

----------------------------------------

--------

---------- ----------

1

ProCurve

J9092A Management Module 8200zl

Active

K.12.30

Primary

2

ProCurve

J9092A Management Module 8200zl

Standby

K.12.30

Primary

1ProCurve J9093A F2 Fabric Module 8200zl Enabled

2ProCurve J9093A F2 Fabric Module 8200zl Enabled

Warning: Standby module is running a different software version and may be using a different configuration file. Configuration changes on active management module may not take effect on a failover.

Figure 15-11. Example of a Software Version Mismatch Between the Active and Standby Modules

15-20